Conclusions
With the larger bonding pitch for the Phi strips of the inner layers, hit finding efficiency (=> track finding efficiency) greatly improves for large f’.
- Track finding efficiency goes up to ~95%, which is what we’ve seen before for optimal conditions (no background and nominal noise)
-
The efficiency does not appear to worsen with the charge sharing as low as 0.4.